T - Standard Series PLC

T24S2T

T24S2T

SeriesStandard PLC
IO Points16DI/8DO, Transistor NPN output
Program Capacity48K
Execution Speed0.05μs/basic instruction
COM PortBuilt-in 1*RS232+ 1*RS485
ProtocolModbus RTU/ASCII, Haiwellbus high-speed protocol, Freedom protocol
Built-in 2 communication ports (RS232 + RS485), can be extended to 5 communication ports. Supports 7 expansion modules at most. Support Haiwell cloud platform,can use Haiwell cloud to do remote programming for Haiwell PLC ,upload/download,firmware upgrade,self-diagnosis,monitor and debug. Easy for remote connection and monitoring the real-time data of the site.
  • Product Introduction
  • Technical Specification
  • File Download

ModelPowerDIDOPulse
Input
Pulse
Output
CommunicationMax
Module
Dimension
T24S2T220V AC168 Transistor
NPN
2 Channels
A/B phase
(4 points)
200KHz
2 Channels
A/B phase
(4 points)
200KHz
RS232+RS485,
up to 5ports
7131*95*82mm



Terminal Wiring Diagram

Haiwell Industry Automation


Product DI specification

Item

Digital Input DI

Input signal

Non-voltage contact or NPN/PNP contact

Action driving

ON: 3.5 mA above OFF: below 1.5 mA

Input impedance

About 4.3KΩ

Input maximum current

10mA

Response time

Default 6.4ms,Configurable 0.8~51.2ms

Isolation mode

Each Channel optical isolation

Input indication

LED light means ON, dark means OFF

Power supply

PLC internal power supply: DC power(sink or source)5.3mA@24VDC

Digital input (DI) wiring diagram

Haiwell Industry Automation


Product DO specification

Item

 Relay Output-R

NPN or PNP transistor output - T/P

maximum load

Resistance load

2A/1 point,8A/4 point per COM

0.5A/1 point,2A/4 point per COM

Inductive load

50VA

5W/24VDC

Light load

100W

12W/24VDC

Min. load

10mA

2mA

Voltage specification

Below 250VAC,30VDC

30VDC

Drive capability

Maximum 5A/250VAC

MAX 1A 10S

Response time

Off-on 10ms,On-off 5ms

Off→On 10μs, On→Off 120μs

Leakage current when route opened

---

Below 0.1mA

Isolation mode

Mechanical isolation

Each Channel optical isolation

Output indication

LED light means ON , dark means OFF

Power supply

PLC internal power supply 24VDC

Digital output (DO) wiring diagram

Haiwell Industry Automation



ItemSpecificationDeclare
Execution speed0.05μs/basic instruction
Program languageLD(ladder) + FBD(function block) 
+ IL( instruction list)
Accord with IEC 61131-3
Program capacity48K
Storage MethodFlash ROM permanent storage, 
dispense with backup battery

XExternal inputX0~X1023Support edge catch and signal
 filtering set
YExternal outputY0~Y1023Power-off preserve output can be 
configured
MAuxiliary relayM0~ M12287Power-off preserve area can be 
set freedom
(default power-off preserve) 
M1536~M2047
TTimer 
(output coil)
T0~T1023Power-off preserve area can be set
 freedom, time base: 10ms, 100ms, 
1s be set freedom,T252~T255 1ms
(default power-off preserve) 
T96~T127
CCounter 
(output coil)
C0~C255Power-off preserve area can be 
set freedom
(default power-off preserve) 
C64~C127
SStep state bitsS0~S2047Power-off preserve area can be 
set Freedom
(default power-off preserve) 
S156~S255
SMSystem state bitsSM0~SM215
LMLocal relayLM~LM31
AIAnalog
 input register
AI0~AI255Support quantities convert, sample 
times and zero point correct
AQAnalog 
output register
AQ0~AQ255Support quantities convert, power-off
 preserve output can be configured
VInternal 
data register
V0~V14847power-off preserve area can be 
set freedom
(default power-off preserve) 
V1000~V2047
TVTimer (Current 
value register)
TV0~TV1023Power-off preserve area can be set
 freedom, time base: 10ms, 100ms, 1s
 can be set freedom, T252~T255 1ms
(default power-off preserve) 
TV96~TV127
CVCounter (Current 
value register)
CV0~CV255Power-off preserve area can be set 
freedom, CV48~CV79 are 32 bits, 
Other are 16 bits 
(default power-off preserve) 
CV64~CV127
SVSystem registerSV0~SV900
LvLocal RegisterLv0~Lv31
PIndexed 
addressing point
P0~P9, use for indirect 
addressing

IInterruptI1-I52
LBLLable255, use for program skip
Communication portMPU built-in 2 communication 
port (RS232/RS485), Max 
5 communication port
 (RS232/RS485) Extension
Can be program or networking 
(master/slave)
Communication protocolModbus RTU/ASCII protocol, 
freedom communication protocol, 
Haiwellbus speed communication
 protocol, Baud rate 1200~115200bps

PLC network capacityPLC communication address
 can be set external set, Max 254, 
support 1: N, N: 1, N: N network

Real time clock (RTC)Display: 
year /month /day
 /hour /minute /second /week
Built-in battery
Float point arithmetic
 instruction
Support within 32 bits float 
point arithmetic, integer/float 
point convert arithmetic

Password protectSupport 3 level password protection:
Program file password
Program block password
PLC hardware password
and upload prohibited function