    H02RS module integrates with two communication ports, while H01RS module only has one communication port, all of Haiwell PLC are expandable to 5 communication ports except E series. Communication exte
  • 请上传图片
    17/08
    Requirements are as follows:1. It is best to use the encoder of 24V power supply;2. The output mode can be the OC gate or the encoder of 24V logic level output such as (push-pull output, NPN or PNP op
  • 请上传图片
    17/08
    Haiwell N series host PLC, according to the different types, there are 4, 6 and 8 channels 200KHz high-speed pulse input independently, and 4, 6 ,8 channels 200KHz high-speed pulse output independentl
  • 请上传图片
    17/08
    Haiwell H series host PLC support 4 channels 200KHz high-speed pulse input independently and 4 channels 200 k high-speed pulse output independently.
  • 请上传图片
    17/08
    Stand-alone supports 8-channel duplex high-speed (200kHz) pulse counting and 7 kinds of counting modes (pulse/direction 1 octave、pulse/direction 2 octave、forward /reverse pulse 1 octave、forward /rever
  • 请上传图片
    17/08
    HHSC instructions of Haiwell high-speed counter support the single-segment comparisons and multi-segment comparisons. The multi-segment comparisons are divided into relative comparison , absolute comp
  • 请上传图片
    17/08
    1. After H32DT module is power-on, if the channel does not connect with any sensor, the indicator will be off. Connect to the sensor in sequence. Read the temperature value and write them to register