POW indicator: Power indicator, green. Always on---Normal power ; Not on---Abnormal power.
AI indicator: Analog input indicator, red. Always on---sensor is connected correctly, Not on----Sensor is not connected or connection is not correct.
LINK light: Communication indicator.
LINK indicator status | Indication | Reference processing method | |
information classification | |||
Always off | Host PLC can not identify the module and no communication | ||
Green | Always on | Normal | |
Host PLC has indentified the module and no communication | |||
Fast jitter | Communication of serial port and parallel port | ||
Red | On-Off flashing | No parallel / serial port communication | Incomplete firmware |
Dark alternates with jitter | parallel / serial port communication | ||
Note: Jitter: The indicator is on for 30ms, off for 30ms ; Flash: The indicator is on for 0.5s, off for 0.5s ; Alternate: The indicator is off for 0.5s , jitter for 0.5s | |||
AI indicator status | Indication | Reference processing method | |
information classification | |||
Red | Always off | No sensor | Normal |
Flashing | Sensor access exception | Check sensor | |
Always on | Sensor access normally | Normal |
APP
© 2005 Xiamen Haiwell Technology Co., Ltd. All Rights Reserved.
4F, No. 336-2, Anbian Nan Road, Torch High-tech Zone (Xiang 'an) Industrial Zone, Xiang 'an District, Xiamen, Fujian, China 361101